articles+ search results
120 articles+ results
1 - 20
Next
Number of results to display per page
1. Rapid prototyping of 3D Organic Electrochemical Transistors by composite photocurable resin [2020]
-
Valentina Bertana, Giorgio Scordo, Matteo Parmeggiani, Luciano Scaltrito, Sergio Ferrero, Manuel Gomez Gomez, Matteo Cocuzza, Davide Vurro, Pasquale D’Angelo, Salvatore Iannotta, Candido F. Pirri, and Simone L. Marasso
- Scientific Reports, Vol 10, Iss 1, Pp 1-11 (2020)
- Subjects
-
Medicine and Science
- Abstract
-
Abstract Rapid Prototyping (RP) promises to induce a revolutionary impact on how the objects can be produced and used in industrial manufacturing as well as in everyday life. Over the time a standard technique as the 3D Stereolithography (SL) has become a fundamental technology for RP and Additive Manufacturing (AM), since it enables the fabrication of the 3D objects from a cost-effective photocurable resin. Efforts to obtain devices more complex than just a mere aesthetic simulacre, have been spent with uncertain results. The multidisciplinary nature of such manufacturing technique furtherly hinders the route to the fabrication of complex devices. A good knowledge of the bases of material science and engineering is required to deal with SL technological, characterization and testing aspects. In this framework, our study aims to reveal a new approach to obtain RP of complex devices, namely Organic Electro-Chemical Transistors (OECTs), by SL technique exploiting a resin composite based on the conductive poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) and the photo curable Poly(ethylene glycol) diacrylate (PEGDA). A comprehensive study is presented, starting from the optimization of composite resin and characterization of its electrochemical properties, up to the 3D OECTs printing and testing. Relevant performances in biosensing for dopamine (DA) detection using the 3D OECTs are reported and discussed too.
- Full text View on content provider's site
-
A. Rodallec, C. Franco, S. Robert, G. Sicard, S. Giacometti, B. Lacarelle, F. Bouquet, A. Savina, R. Lacroix, F. Dignat-George, J. Ciccolini, P. Poncelet, and R. Fanciullino
- Scientific Reports, Vol 10, Iss 1, Pp 1-11 (2020)
- Subjects
-
Medicine and Science
- Abstract
-
Abstract Developing targeted nanoparticles is a rising strategy to improve drug delivery in oncology. Antibodies are the most commonly used targeting agents. However, determination of their optimal number at the surface remains a challenging issue, mainly due to the difficulties in measuring precisely surface coating levels when prototyping nanoparticles. We developed an original quantitative assay to measure the exact number of coated antibodies per nanoparticle. Using flow cytometry optimized for submicron particle analysis and beads covered with known amounts of human IgG-kappa mimicking various amounts of antibodies, this new method was tested as part of the prototyping of docetaxel liposomes coated with trastuzumab against Her2+ breast cancer. This quantification method allowed to discriminate various batches of immunoliposomes depending on their trastuzumab density on nanoparticle surface (i.e., 330 (Immunoliposome-1), 480 (Immunoliposome-2) and 690 (Immunoliposome-3), p = 0.004, One-way ANOVA). Here we showed that optimal number of grafted antibodies on nanoparticles should be finely tuned and highest density of targeting agent is not necessarily associated with highest efficacy. Overall, this new method should help to better prototype third generation nanoparticles.
- Full text View on content provider's site
-
Michaela L Comrie, Gabrielle Monteith, Alex Zur Linden, Michelle Oblak, John Phillips, Fiona M K James, and Ontario Veterinary College Rapid Prototyping of Patient-specific Implants for Dogs (RaPPID) group
- PLoS ONE, Vol 14, Iss 3, p e0214123 (2019)
- Subjects
-
Medicine and Science
- Abstract
-
This study's objective was to determine the accuracy of using current computed tomography (CT) scan and software techniques for rapid prototyping by quantifying the margin of error between CT models and laser scans of canine skull specimens. Twenty canine skulls of varying morphology were selected from an anatomy collection at a veterinary school. CT scans (bone and standard algorithms) were performed for each skull, and data segmented (testing two lower threshold settings of 226HU and -650HU) into 3-D CT models. Laser scans were then performed on each skull. The CT models were compared to the corresponding laser scan to determine the error generated from the different types of CT model parameters. This error was then compared between the different types of CT models to determine the most accurate parameters. The mean errors for the 226HU CT models, both bone and standard algorithms, were not significant from zero error (p = 0.1076 and p = 0.0580, respectively). The mean errors for both -650HU CT models were significant from zero error (p < 0.001). Significant differences were detected between CT models for 3 CT model comparisons: Bone (p < 0.0001); Standard (p < 0.0001); and -650HU (p < 0.0001). For 226HU CT models, a significant difference was not detected between CT models (p = 0.2268). Independent of the parameters tested, the 3-D models derived from CT imaging accurately represent the real skull dimensions, with CT models differing less than 0.42 mm from the real skull dimensions. The 226HU threshold was more accurate than the -650HU threshold. For the 226HU CT models, accuracy was not dependent on the CT algorithm. For the -650 CT models, bone was more accurate than standard algorithms. Knowing the inherent error of this procedure is important for use in 3-D printing for surgical planning and medical education.
- Full text
View/download PDF
-
S. R. A. Kratz, C. Eilenberger, P. Schuller, B. Bachmann, S. Spitz, P. Ertl, and M. Rothbauer
- Scientific Reports, Vol 9, Iss 1, Pp 1-12 (2019)
- Subjects
-
Medicine and Science
- Abstract
-
Abstract In the advent of affordable photo- and soft-lithography using polydimethylsiloxane (PDMS), low cost multi-step microfabrication methods have become available to a broad scientific community today. Although these methods are frequently applied for microfluidic prototype production in academic and industrial settings, fast design iterations and rapid prototyping within a few minutes with a high degree of flexibility are nearly impossible. To reduce microfluidic concept-to-chip time and costs, a number of alternative rapid prototyping techniques have recently been introduced including CNC micromachining, 3D printing and plotting out of numeric CAD designs as well as micro-structuring of thin PDMS sheets and pressure sensitive adhesives. Although micro-structuring of pressure sensitive adhesives promises high design flexibility, rapid fabrication and simple biochip assembly, most adhesives are toxic for living biological systems. Since an appropriate bio-interface and proper biology-material interaction is key for any cell chip and organ-on-a-chip system, only a limited number of medical-grade materials are available for microfluidic prototyping. In this study, we have characterized four functional biomedical-grade pressure sensitive adhesives for rapid prototyping (e.g. less than 1 hour) applications including structuring precision, physical and optical properties as well as biocompatibilities. While similar biocompatibility was found for all four adhesives, significant differences in cutting behavior, bonding strength to glass and polymers as well as gas permeability was observed. Practical applications included stability testing of multilayered, membrane-integrated organ-on-a-chip devices under standard cell culture conditions (e.g. 2–3 weeks at 37 °C and 100% humidity) and a shear-impact up to 5 dynes/cm2. Additionally, time- and shear-dependent uptake of non-toxic fluorescently labelled nanoparticles on human endothelial cells are demonstrated using micro-structured adhesive-bonded devices. Our results show that (a) both simple and complex microdevices can be designed, fabricated and tested in less than 1 hour, (b) these microdevices are stable for weeks even under physiological shear force conditions and (c) can be used to maintain cell monolayers as well as 3D cell culture systems.
- Full text View on content provider's site
-
Verjans Mark, Asseln Malte, and Radermacher Klaus
- Current Directions in Biomedical Engineering, Vol 2, Iss 1, Pp 553-556 (2016)
- Subjects
-
biomechanics, knee simulator, rapid prototyping, total knee arthroplasty, and Medicine
- Abstract
-
The understanding of the complex biomechanics of the knee is a key for an optimal implant design. To easily investigate the influence of prosthetic designs on knee biomechanics a rapid prototyping workflow for knee implants has been developed and evaluated. Therefore, different manufacturing technologies and post-treatment methods have been examined and overall seven different replica knee implants were manufactured. For evaluation, the manufacturing properties such as surface accuracy and roughness were determined and kinematic behaviour was investigated in a novel knee testing rig. It was carried out that PolyJet-Modelling with a sanded surface resulted in changed kinematic patterns compared to a usual CoCr-UHMWPE implant. However, fused deposition modelling using ABS and subsequent surface smoothening with acetone vapor showed the lowest roughness of the manufactured implants and only minor kinematic differences. For this reason this method constitutes a promising approach towards an optimal implant design for improved patient-satisfaction and long lifetime of the implant. Finally the workflow is not only limited to the knee.
- Full text View on content provider's site
6. Cost-effective rapid prototyping and assembly of poly(methyl methacrylate) microfluidic devices [2018]
-
Carlos Matellan and Armando E. del Río Hernández
- Scientific Reports, Vol 8, Iss 1, Pp 1-13 (2018)
- Subjects
-
Medicine and Science
- Abstract
-
Abstract The difficulty in translating conventional microfluidics from laboratory prototypes to commercial products has shifted research efforts towards thermoplastic materials for their higher translational potential and amenability to industrial manufacturing. Here, we present an accessible method to fabricate and assemble polymethyl methacrylate (PMMA) microfluidic devices in a “mask-less” and cost-effective manner that can be applied to manufacture a wide range of designs due to its versatility. Laser micromachining offers high flexibility in channel dimensions and morphology by controlling the laser properties, while our two-step surface treatment based on exposure to acetone vapour and low-temperature annealing enables improvement of the surface quality without deformation of the device. Finally, we demonstrate a capillarity-driven adhesive delivery bonding method that can produce an effective seal between PMMA devices and a variety of substrates, including glass, silicon and LiNbO3. We illustrate the potential of this technique with two microfluidic devices, an H-filter and a droplet generator. The technique proposed here offers a low entry barrier for the rapid prototyping of thermoplastic microfluidics, enabling iterative design for laboratories without access to conventional microfabrication equipment.
- Full text View on content provider's site
-
Vasilina V. Rocheva, Anastasia V. Koroleva, Alexander G. Savelyev, Kirill V. Khaydukov, Alla N. Generalova, Andrey V. Nechaev, Anna E. Guller, Vladimir A. Semchishen, Boris N. Chichkov, and Evgeny V. Khaydukov
- Scientific Reports, Vol 8, Iss 1, Pp 1-10 (2018)
- Subjects
-
Medicine and Science
- Abstract
-
Abstract Three-dimensional (3D) rapid prototyping technology based on near-infrared light-induced polymerization of photocurable compositions containing upconversion nanomaterials has been explored. For this aim, the rationally-designed core/shell upconversion nanoparticles NaYF4:Yb3+,Tm3+/NaYF4, with the distinct ultraviolet-emitting lines and unprecedentedly high near-infrared to ultraviolet conversion efficiency of $${\eta }_{{\bf{UC}}}^{({\bf{UV}})}=2{\boldsymbol{ \% }}$$ ηUC(UV)=2% have been used. The upconverted ultraviolet photons were capable to efficiently activate photoinitiators contained in light-sensitive resins under moderate intensities of NIR excitation below 10 W cm−2 and induce generation of radicals and photopolymerization in situ. Near infrared-activated polymerization process, both at the millimeter and sub-micron scales, was investigated. Polymeric macro- and microstructures were fabricated by means of near infrared laser scanning photolithography in the volume of liquid photocurable compositions with focused laser light at 975 nm wavelength. Examination of the polymerization process in the vicinity of the nanoparticles shows strong differences in the rate of polymer shell growth on flat and edge nanoparticle sides. This phenomenon mainly defines the resolution of the demonstrated near infrared - ultraviolet 3D printing technology at the micrometer scale level.
- Full text View on content provider's site
8. Rapid Prototyping of Polymeric Nanopillars by 3D Direct Laser Writing for Controlling Cell Behavior [2017]
-
Nina Buch-Månson, Arnaud Spangenberg, Laura Piedad Chia Gomez, Jean-Pierre Malval, Olivier Soppera, and Karen L. Martinez
- Scientific Reports, Vol 7, Iss 1, Pp 1-9 (2017)
- Subjects
-
Medicine and Science
- Abstract
-
Abstract Mammalian cells have been widely shown to respond to nano- and microtopography that mimics the extracellular matrix. Synthetic nano- and micron-sized structures are therefore of great interest in the field of tissue engineering, where polymers are particularly attractive due to excellent biocompatibility and versatile fabrication methods. Ordered arrays of polymeric pillars provide a controlled topographical environment to study and manipulate cells, but processing methods are typically either optimized for the nano- or microscale. Here, we demonstrate polymeric nanopillar (NP) fabrication using 3D direct laser writing (3D DLW), which offers a rapid prototyping across both size regimes. The NPs are interfaced with NIH3T3 cells and the effect of tuning geometrical parameters of the NP array is investigated. Cells are found to adhere on a wide range of geometries, but the interface depends on NP density and length. The Cell Interface with Nanostructure Arrays (CINA) model is successfully extended to predict the type of interface formed on different NP geometries, which is found to correlate with the efficiency of cell alignment along the NPs. The combination of the CINA model with the highly versatile 3D DLW fabrication thus holds the promise of improved design of polymeric NP arrays for controlling cell growth.
- Full text View on content provider's site
-
Fariba Ghaderinezhad, Reza Amin, Mikail Temirel, Bekir Yenilmez, Adam Wentworth, and Savas Tasoglu
- Scientific Reports, Vol 7, Iss 1, Pp 1-9 (2017)
- Subjects
-
Medicine and Science
- Abstract
-
Abstract Paper-based micro analytical devices offer significant advantages compared to the conventional microfluidic chips including cost-effectiveness, ease of fabrication, and ease of use while preserving critical features including strong capillary action and biological compatibility. In this work, we demonstrate an inexpensive, rapid method for high-throughput fabrication of paper-based microfluidics by patterning hydrophobic barriers using a desktop pen plotter integrated with a custom-made, low-cost paper feeder. We tested various types of commercial permanent markers and compared their water-resistant capabilities for creating hydrophobic barriers. Additionally, we studied the performance of markers with different types of paper, plotting speeds, and pattern dimensions. To verify the effectiveness of the presented fabrication method, colorimetric analysis was performed on the results of a glucose assay.
- Full text View on content provider's site
-
Ariane Plaisance, Holly O Witteman, Annie LeBlanc, Jennifer Kryworuchko, Daren Keith Heyland, Mark H Ebell, Louisa Blair, Diane Tapp, Audrey Dupuis, Carole-Anne Lavoie-Bérard, Carrie Anna McGinn, France Légaré, and Patrick Michel Archambault
- PLoS ONE, Vol 13, Iss 2, p e0191844 (2018)
- Subjects
-
Medicine and Science
- Abstract
-
Upon admission to an intensive care unit (ICU), all patients should discuss their goals of care and express their wishes concerning life-sustaining interventions (e.g., cardiopulmonary resuscitation (CPR)). Without such discussions, interventions that prolong life at the cost of decreasing its quality may be used without appropriate guidance from patients.To adapt an existing decision aid about CPR to create a wiki-based decision aid individually adapted to each patient's risk factors; and to document the use of a wiki platform for this purpose.We conducted three weeks of ethnographic observation in our ICU to observe intensivists and patients discussing goals of care and to identify their needs regarding decision making. We interviewed intensivists individually. Then we conducted three rounds of rapid prototyping involving 15 patients and 11 health professionals. We recorded and analyzed all discussions, interviews and comments, and collected sociodemographic data. Using a wiki, a website that allows multiple users to contribute or edit content, we adapted the decision aid accordingly and added the Good Outcome Following Attempted Resuscitation (GO-FAR) prediction rule calculator.We added discussion of invasive mechanical ventilation. The final decision aid comprises values clarification, risks and benefits of CPR and invasive mechanical ventilation, statistics about CPR, and a synthesis section. We added the GO-FAR prediction calculator as an online adjunct to the decision aid. Although three rounds of rapid prototyping simplified the information in the decision aid, 60% (n = 3/5) of the patients involved in the last cycle still did not understand its purpose.Wikis and user-centered design can be used to adapt decision aids to users' needs and local contexts. Our wiki platform allows other centers to adapt our tools, reducing duplication and accelerating scale-up. Physicians need training in shared decision making skills about goals of care and in using the decision aid. A video version of the decision aid could clarify its purpose.
- Full text
View/download PDF
-
Shuai Guo, Teng Lu, Qiaolong Hu, Baohui Yang, Xijing He, and Haopeng Li
- BioMed Research International, Vol 2016 (2016)
- Subjects
-
Medicine
- Abstract
-
Purpose. To preliminarily evaluate the feasibility and accuracy of using rapid prototyping drill templates (RPDTs) for C1 lateral mass screw (C1-LMS) and C2 pedicle screw (C2-PS) placement. Methods. 23 formalin-fixed craniocervical cadaver specimens were randomly divided into two groups. In the conventional method group, intraoperative fluoroscopy was used to assist the screw placement. In the RPDT navigation group, specific RPDTs were constructed for each specimen and were used intraoperatively for screw placement navigation. The screw position, the operating time, and the fluoroscopy time for each screw placement were compared between the 2 groups. Results. Compared with the conventional method, the RPDT technique significantly increased the placement accuracy of the C2-PS (p0.05). Moreover, the RPDT technique significantly decreased the operating and fluoroscopy times. Conclusion. Using RPDTs significantly increases the accuracy of C1-LMS and C2-PS placement while decreasing the screw placement time and the radiation exposure. Due to these advantages, this approach is worth promoting for use in the Harms technique.
- Full text
View/download PDF
-
Harley H L Chan, Jeffrey H Siewerdsen, Allan Vescan, Michael J Daly, Eitan Prisman, and Jonathan C Irish
- PLoS ONE, Vol 10, Iss 9, p e0136370 (2015)
- Subjects
-
Medicine and Science
- Abstract
-
The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques across a variety of otolaryngological sub-specialties suggests an emerging role for rapid prototyping technology in surgical education, procedure simulation, and clinical practice.
- Full text
View/download PDF
-
Jayesh Dhanani, George Pang, Jason Pincus, Benjamin Ahern, Wendy Goodwin, Nicholas Cowling, Grant Whitten, Mohd. H. Abdul-Aziz, Steven Martin, Peter Corke, and Kevin B. Laupland
- BMC Research Notes, Vol 13, Iss 1, Pp 1-6 (2020)
- Subjects
-
Ventilators, Pandemic, COVID 19, Mass disaster, Rapid prototyping, 3 D printing, Medicine, Biology (General), QH301-705.5, Science (General), and Q1-390
- Abstract
-
Abstract Objective The advent of new technologies has made it possible to explore alternative ventilator manufacturing to meet the worldwide shortfall for mechanical ventilators especially in pandemics. We describe a method using rapid prototyping technologies to create an electro-mechanical ventilator in a cost effective, timely manner and provide results of testing using an in vitro–in vivo testing model. Results Rapid prototyping technologies (3D printing and 2D cutting) were used to create a modular ventilator. The artificial manual breathing unit (AMBU) bag connected to wall oxygen source using a flow meter was used as air reservoir. Controlled variables include respiratory rate, tidal volume and inspiratory: expiratory (I:E) ratio. In vitro testing and In vivo testing in the pig model demonstrated comparable mechanical efficiency of the test ventilator to that of standard ventilator but showed the material limits of 3D printed gears. Improved gear design resulted in better ventilator durability whilst reducing manufacturing time (
- Full text View on content provider's site
-
Farshad Tehrani, Lisa Reiner, and Behzad Bavarian
- PLoS ONE, Vol 10, Iss 12, p e0145036 (2015)
- Subjects
-
Medicine and Science
- Abstract
-
A rapid prototyping of an inexpensive, disposable graphene and copper nanocomposite sensor strip using polymeric flexible substrate for highly sensitive and selective nonenzymatic glucose detection has been developed and tested for direct oxidization of glucose. The CuNPs were electrochemically deposited on to the graphene sheets to improve electron transfer rates and to enhance electrocatalytic activity toward glucose. The graphene based electrode with CuNPs demonstrated a high degree of sensitivity (1101.3 ± 56 μA/mM.cm2), excellent selectivity (without an interference with Ascorbic Acid, Uric Acid, Dopamine, and Acetaminophen), good stability with a linear response to glucose ranging from 0.1 mM to 0.6 mM concentration, and detection limits of 0.025 mM to 0.9 mM. Characterization of the electrodes was performed by scanning electron microscopy (FESEM and SEM). The electrochemical properties of the modified graphene electrodes were inspected by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and amperometry.
- Full text
View/download PDF
15. New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations. [2015]
-
Luis Romero, Mariano Jiménez, María Del Mar Espinosa, and Manuel Domínguez
- PLoS ONE, Vol 10, Iss 12, p e0145253 (2015)
- Subjects
-
Medicine and Science
- Abstract
-
This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system.From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data.Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants.
- Full text
View/download PDF
-
Zou Q, Jin J, Huang T, and Chu Y
Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation [Zhongguo Yi Liao Qi Xie Za Zhi] 2019 Jul 30; Vol. 43 (4), pp. 279-281.
- Subjects
-
Research trends, Medicine trends, and Printing, Three-Dimensional
- Abstract
-
3D printing technology is a kind of manufacturing technology for increasing materials. Based on its advantages of rapid prototyping, digitalization and customization, it can effectively meet the needs of personalized and accurate medical treatment, and has been widely studied and applied in the medical field. This paper introduces the principle, technology and materials of 3D printing technology, and describes the research and application status of the technology in medical field. Meanwhile, some problems of 3D printing technology existing in the current development and its future application prospects also will be discussed.
- Full text View on content provider's site
-
Giorgio Pompa, Stefano Di Carlo, Francesca De Angelis, Maria Paola Cristalli, and Susanna Annibali
- BioMed Research International, Vol 2015 (2015)
- Subjects
-
Medicine
- Abstract
-
This study assessed whether there are differences in marginal fit between laser-fusion and conventional techniques to produce fixed dental prostheses (FDPs). A master steel die with 2 abutments was produced to receive a posterior 4-unit FDPs and single copings. These experimental models were divided into three groups (n=20/group) manufactured: group 1, Ni-Cr alloy, with a lost-wax casting technique; group 2, Co-Cr alloy, with selective laser melting (SLM); and group 3, yttria-tetragonal zirconia polycrystal (Y-TZP), with a milling system. All specimens were cut along the longitudinal axis and their adaptation was measured at the marginal and shoulder areas on the right and left sides of each abutment. Measurements were made using a stereomicroscope (×60 magnification) and a scanning electron microscope (×800 magnification). The data were analyzed using one-way analysis of variance and the Bonferroni post hoc test, with a significance cutoff of 5%. Significant differences (P
- Full text
View/download PDF
-
Christian Schröder, Arnd Steinbrück, Tatjana Müller, Matthias Woiczinski, Yan Chevalier, Patrick Weber, Peter E. Müller, and Volkmar Jansson
- BioMed Research International, Vol 2015 (2015)
- Subjects
-
Medicine
- Abstract
-
Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components for in vitro tests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM) by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM) prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE) were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components for in vitro TKA studies and future investigations on knee biomechanics.
- Full text
View/download PDF
-
Matjaž Merc, Igor Drstvenšek, Matjaž Vogrin, Tomaž Brajlih, and Gregor Rečnik
- Zdravniški Vestnik, Vol 82, Iss 6 (2013)
- Subjects
-
Medicine
- Abstract
-
Background: Pedicle screw placement using free hand technique has high incidence of pedicle perforation. The said risk can be reduced with intra-operative fluoroscopy or navigation, which have some disadvantages. A promising principle for solving most of the issues is the rapid prototyping technology. By this technique it is possible to manufacture patient specific drill guide templates that enable optimal pedicle screw placement. In the last decade, many studies have featured relatively successful implantations of pedicle screws through the use of drill guide templates, though mostly on cadavers. We performed a similar clinical study involving the manufacture of templates for the lumbar and sacral regions that enable simultaneous multiple- level screw implanting. Methods: A randomized clinical trial was performed in 15 patients. In the lumbar and sacral spine 30 screws were implanted using drill guide template and 36 screws using free hand technique under fluoroscopy supervision. Preoperative CT-scans were taken for drill guide template design and manufacture using selective laser sintering method. According to postoperative CTscan analysis, pedicle perforation incidence was estimated. Results: The incidence of cortex perforation was significantly reduced in the drill guide template group. Conclusions: Drill guide templates have turned out to be a reliable solution that importantly reduces pedicle perforation incidence and complications related to it. However, there are shortcomings: a relatively lengthy manufacturing process, possible manufacturing faults and incorrect positioning during the operation. Owing to mentioned disadvantages, templates have not replaced free hand and navigation technique yet, but could represent a useful tool in some selected cases.
- Full text View on content provider's site
-
Mark Frame and James S. Huntley
- The Scientific World Journal, Vol 2012 (2012)
- Subjects
-
Technology, Medicine, and Science
- Abstract
-
Rapid prototyping (RP) is applicable to orthopaedic problems involving three dimensions, particularly fractures, deformities, and reconstruction. In the past, RP has been hampered by cost and difficulties accessing the appropriate expertise. Here we outline the history of rapid prototyping and furthermore a process using open-source software to produce a high fidelity physical model from CT data. This greatly mitigates the expense associated with the technique, allowing surgeons to produce precise models for preoperative planning and procedure rehearsal. We describe the method with an illustrative case.
- Full text View on content provider's site
Catalog
Books, media, physical & digital resources
Guides
Course- and topic-based guides to collections, tools, and services.
1 - 20
Next