articles+ search results
4 articles+ results
1 - 4
Number of results to display per page
1. Development of Personalized Annuloplasty Rings: Combination of CT Images and CAD-CAM Tools [2010]
-
Díaz Lantada, Andrés, Valle-Fernández, Raquel Del, Morgado, Pilar Lafont, Muñoz-García, Julio, Muñoz Sanz, José Luis, Munoz-Guijosa, Juan Manuel, and Otero, Javier Echávarri
- Annals of biomedical engineering, 2010 Feb., v. 38, no. 2, p. 280-290.
- Abstract
-
Includes references
Although the use of personalized annuloplasty rings manufactured for each patient according to the size and morphology of their valve complex could be beneficial for the treatment of mitral insufficiency, this possibility has been limited for reasons of timelines and costs as well as for design and manufacturing difficulties, as has been the case with other personalized implant and prosthetic developments. However, the present quality of medical image capture equipment together with the benefits to be had from computer-aided design and manufacturing technologies (CAD-CAM) and the capabilities furnished by rapid prototyping technologies, present new opportunities for a personalized response to the development of implants and prostheses, the social impact of which could turn out to be highly positive. This paper sets out a personalized development of an annuloplasty ring based on the combined use of information from medical imaging, from CAD-CAM design programs and prototype manufacture using rapid prototyping technologies.
- Full text View on content provider's site
-
Thomas, Marlon S., Millare, Brent, Clift, Joseph M., Bao, Duoduo, Hong, Connie, and Vullev, Valentine I.
- Annals of biomedical engineering, 2010 Jan., v. 38, no. 1, p. 21-32.
- Abstract
-
Includes references
This article reviews the development and the advances of print-and-peel (PAP) microfabrication. PAP techniques provide means for facile and expedient prototyping of microfluidic devices. Therefore, PAP has the potential for broadening the microfluidics technology by bringing it to researchers who lack regular or any accesses to specialized fabrication facilities and equipment. Microfluidics have, indeed, proven to be an indispensable toolkit for biological and biomedical research and development. Through accessibility to such methodologies for relatively fast and easy prototyping, PAP has the potential to considerably accelerate the impacts of microfluidics on the biological sciences and engineering. In summary, PAP encompasses: (1) direct printing of the masters for casting polymer device components; and (2) adding three-dimensional elements onto the masters for single-molding-step formation of channels and cavities within the bulk of the polymer slabs. Comparative discussions of the different PAP techniques, along with the current challenges and approaches for addressing them, outline the perspectives for PAP and how it can be readily adopted by a broad range of scientists and engineers.
- Full text View on content provider's site
-
Wen, Chih-Yung, Yang, An-Shik, Tseng, Li-Yu, and Chai, Jyh-Wen
- Annals of biomedical engineering, 2010 Feb., v. 38, no. 2, p. 391-402.
- Abstract
-
Includes references
Cardiovascular disease is the primary cause of morbidity and mortality in the western world. Complex hemodynamics plays a critical role in the development of aortic dissection and atherosclerosis, as well as many other diseases. Since fundamental fluid mechanics are important for the understanding of the blood flow in the cardiovascular circulatory system of the human body aspects, a joint experimental and numerical study was conducted in this study to determine the distributions of wall shear stress and pressure and oscillatory WSS index, and to examine their correlation with the aortic disorders, especially dissection. Experimentally, the Phase-Contrast Magnetic Resonance Imaging (PC-MRI) method was used to acquire the true geometry of a normal human thoracic aorta, which was readily converted into a transparent thoracic aorta model by the rapid prototyping (RP) technique. The thoracic aorta model was then used in the in vitro experiments and computations. Simulations were performed using the computational fluid dynamic (CFD) code ACE+® to determine flow characteristics of the three-dimensional, pulsatile, incompressible, and Newtonian fluid in the thoracic aorta model. The unsteady boundary conditions at the inlet and the outlet of the aortic flow were specified from the measured flowrate and pressure results during in vitro experiments. For the code validation, the predicted axial velocity reasonably agrees with the PC-MRI experimental data in the oblique sagittal plane of the thoracic aorta model. The thorough analyses of the thoracic aorta flow, WSSs, WSS index (OSI), and wall pressures are presented. The predicted locations of the maxima of WSS and the wall pressure can be then correlated with that of the thoracic aorta dissection, and thereby may lead to a useful biological significance. The numerical results also suggest that the effects of low WSS and high OSI tend to cause wall thickening occurred along the inferior wall of the aortic arch and the anterior wall of the brachiocephalic artery, similar implication reported in a number of previous studies.
- Full text View on content provider's site
-
FORTUNA, A. De O and GURD, J. R
- Annals of biomedical engineering. 27(3):356-365
- Subjects
-
Biotechnology, Biotechnologies, Biomedical engineering, Génie biomédical, Sciences biologiques et medicales, Biological and medical sciences, Sciences medicales, Medical sciences, Techniques d'exploration et de diagnostic (generalites), Investigative techniques, diagnostic techniques (general aspects), Exploration fonctionnelle respiratoire, Investigative techniques of respiratory function, Appareil respiratoire, Respiratory system, Aparato respiratorio, Génie biomédical, Biomedical engineering, Ingeniería biomédica, Appareillage, Instrumentation, Instrumentación, Capteur débit, Flowmeter(sensor), Captador flujo, Complication, Complicación, Débitmétrie, Flowmetry, Caudalimetría, Ecoulement orifice, Orifice flow, Flujo orificio, Evaluation performance, Performance evaluation, Evaluación prestación, Fonction respiratoire, Lung function, Función respiratoria, Forme géométrique, Geometrical shape, Forma geométrica, Homme, Human, Hombre, Monitorage, Monitoring, Monitoreo, Optimisation, Optimization, Optimización, Orifice, Orificio, Plaque, Plate, Placa, Sécrétat trachéobronchique, Tracheobronchial secretion, and Excreto traqueobronquial
- Abstract
-
During certain medical procedures, it is important to continuously measure the respiratory flow of a patient, as lack of proper ventilation can cause brain damage and ultimately death. The monitoring of the ventilatory condition of a patient is usually performed with the aid of flowmeters. However, water and other secretions present in the expired air can build up and ultimately block a traditional, restriction-based flowmeter; by using an orilice plate flowmeter, such blockages are minimized. This paper describes the design of an orifice plate flowmetering system including, especially, a description of the numerical and computational techniques adopted in order to simulate human respiratory and sinusoidal air flow across various possible designs for the orifice plate flowmeter device. Parallel computation and multigrid techniques were employed in order to reduce execution time. The simulated orifice plate was later built and tested under unsteady sinusoidal flows. Experimental tests show reasonable agreement with the numerical simulation, thereby reinforcing the general hypothesis that computational exploration of the design space is sufficiently accurate to allow designers of such systems to use this in preference to the more traditional, mechanical prototyping techniques.
- Full text View on content provider's site
Catalog
Books, media, physical & digital resources
Guides
Course- and topic-based guides to collections, tools, and services.