Fang Y, Chen F, Wu H, and Chen B
Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie [Graefes Arch Clin Exp Ophthalmol] 2023 Apr; Vol. 261 (4), pp. 903-912. Date of Electronic Publication: 2022 Dec 15.
- Abstract
-
Three-dimensional printing (3DP) technology is a rapid prototyping technology that is widely used in the medical field. It can be combined with computer-aided design, material manufacturing, and other technologies to construct medical-related appliances, human implants and even cell-based models or biological tissues. In the field of ophthalmology, the technology can be used to manufacture ocular anatomical models, glasses, intraocular implants, microsurgical instruments, drugs, etc. It can also enable future 'bioprinting', involving the refractive and nervous systems of the eyeball, with excellent development prospects in the field. This review introduces the development of 3DP technology in ophthalmology and discusses its application and potential.
(© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)
- Full text View on content provider's site
-
García-Moll L, Sixto A, Carrasco-Correa EJ, and Miró M
Talanta [Talanta] 2023 Apr 01; Vol. 255, pp. 124211. Date of Electronic Publication: 2022 Dec 24.
- Subjects
-
Printing, Three-Dimensional, Hydrogen Peroxide, and Luminescence
- Abstract
-
Low force stereolithography is exploited for the first time for one-step facile fabrication of chemiluminescence (CL) flow-through cells that bear unrivalled features as compared to those available through milling or blowing procedures or alternative 3D printing technologies. A variety of bespoke cross-section geometries with polyhedral features (namely, triangular, square, and five-side polygon) as well as semicircular cross-section are herein critically evaluated in terms of analytical performance against the standardcircular cross-section in a flat spirally-shape format. The idea behind is to maximize capture of elicited light by the new designs while leveraging 3D printing further for fabrication of (i) customized gaskets that enable reliable attaching of the active mixing zone of the CL cell to the detection window, (ii) in-line 3D-printed serpentine reactors, and (iii) flow confluences with tailorable shapes for enhancing mixing of samples with CL reagents. Up to twenty transparent functional cells were simultaneously fabricated without inner supports following post-curing and surface treatment protocols lasting less than 5 h. In fact, previous attempts to print spirally-shaped cells in one-step by resorting to less cost effective photopolymer inkjet printing technologies were unsuccessful because of the requirement of lengthy procedures (>15 days) for quantitative removal of the support material. By exploiting the phthalazinedione-hydrogen peroxide chemistry as a model reaction, the five-side irregular pentagon cell exhibited superior analytical figures of merit in terms of LOD, dynamic range and intermediate precision as compared to alternative designs. Computational fluid dynamic simulations for mapping velocities at the entry region of the spiral cell corroborated the fact that the 5-side polygon cross-section flow-cell with Y-type confluence permitted the most efficient mixing of reagents and sample while enabling larger flow velocities near the inlet that contribute to a more efficient capture of the photons from the flash-type reaction. The applicability of the 3D-printed 5-side polygon CL cell for automatic determination of hydrogen peroxide using a computerized hybrid flow system was demonstrated for the analysis of high matrix samples, viz., seawater and saliva, with relative recoveries ranging from 83 to 103%.
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2023 Elsevier B.V. All rights reserved.)
- Full text View on content provider's site
-
Rüfenacht E, Kamath A, Suter Y, Poel R, Ermiş E, Scheib S, and Reyes M
Computer methods and programs in biomedicine [Comput Methods Programs Biomed] 2023 Apr; Vol. 231, pp. 107374. Date of Electronic Publication: 2023 Jan 28.
- Subjects
-
Humans, Organs at Risk, Image Processing, Computer-Assisted methods, and Tomography, X-Ray Computed methods
- Abstract
-
Background and Objective: Despite fast evolution cycles in deep learning methodologies for medical imaging in radiotherapy, auto-segmentation solutions rarely run in clinics due to the lack of open-source frameworks feasible for processing DICOM RT Structure Sets. Besides this shortage, available open-source DICOM RT Structure Set converters rely exclusively on 2D reconstruction approaches leading to pixelated contours with potentially low acceptance by healthcare professionals. PyRaDiSe, an open-source, deep learning framework independent Python package, addresses these issues by providing a framework for building auto-segmentation solutions feasible to operate directly on DICOM data. In addition, PyRaDiSe provides profound DICOM RT Structure Set conversion and processing capabilities; thus, it applies also to auto-segmentation-related tasks, such as dataset construction for deep learning model training.
Methods: The PyRaDiSe package follows a holistic approach and provides DICOM data handling, deep learning model inference, pre-processing, and post-processing functionalities. The DICOM data handling allows for highly automated and flexible handling of DICOM image series, DICOM RT Structure Sets, and DICOM registrations, including 2D-based and 3D-based conversion from and to DICOM RT Structure Sets. For deep learning model inference, extending given skeleton classes is straightforwardly achieved, allowing for employing any deep learning framework. Furthermore, a profound set of pre-processing and post-processing routines is included that incorporate partial invertibility for restoring spatial properties, such as image origin or orientation.
Results: The PyRaDiSe package, characterized by its flexibility and automated routines, allows for fast deployment and prototyping, reducing efforts for auto-segmentation pipeline implementation. Furthermore, while deep learning model inference is independent of the deep learning framework, it can easily be integrated into famous deep learning frameworks such as PyTorch or Tensorflow. The developed package has successfully demonstrated its capabilities in a research project at our institution for organs-at-risk segmentation in brain tumor patients. Furthermore, PyRaDiSe has shown its conversion performance for dataset construction.
Conclusions: The PyRaDiSe package closes the gap between data science and clinical radiotherapy by enabling deep learning segmentation models to be easily transferred into clinical research practice. PyRaDiSe is available on https://github.com/ubern-mia/pyradise and can be installed directly from the Python Package Index using pip install pyradise.
Competing Interests: Declaration of Competing Interest Authors declare that they have no conflict of interest.
(Copyright © 2023 The Author(s). Published by Elsevier B.V. All rights reserved.)
- Full text View on content provider's site
-
Awad S, Amon K, Baillie A, Loveday T, and Baysari MT
International journal of medical informatics [Int J Med Inform] 2023 Apr; Vol. 172, pp. 105017. Date of Electronic Publication: 2023 Feb 09.
- Subjects
-
Humans, Medication Systems, Hospital, Patient Safety, Medication Therapy Management, and Medical Order Entry Systems
- Abstract
-
Introduction: Poorly designed electronic medication management systems (EMMS) or computerized physician order entry (CPOE) systems in hospital settings can result in usability issues and in turn, patient safety risks. As a safety science, human factors and safety analysis methods have potential to support the safe and usable design of EMMS.
Objective: To identify and describe human factors and safety analysis methods that have been used in the design or redesign of EMMS used in hospital settings.
Materials and Methods: A systematic review, following PRISMA guidelines, was conducted by searching online databases and relevant journals from January 2011 to May 2022. Studies were included if they described the practical application of human factors and safety analysis methods to support the design or redesign of a clinician-facing EMMS, or its components. Methods used were extracted and mapped to human centered design (HCD) activities: understanding context of use; specifying user requirements; producing design solutions; and evaluating the design.
Results: Twenty-one papers met the inclusion criteria. Overall, 21 human factors and safety analysis methods were used in the design or redesign of EMMS with prototyping, usability testing, participant surveys/questionnaires and interviews the most frequent. Human factors and safety analysis methods were most frequently used to evaluate the design of a system (n = 67; 56.3%). Nineteen of 21 (90%) methods used aimed to identify usability issues and/or support iterative design; only one paper utilized a safety-oriented method and one, a mental workload assessment method.
Discussion and Conclusion: While the review identified 21 methods, EMMS design primarily utilized a subset of available methods, and rarely a method focused on safety. Given the high-risk nature of medication management in complex hospital environments, and the potential for harm due to poorly designed EMMS, there is significant potential to apply more safety-oriented human factors and safety analysis methods to support EMMS design.
Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2023 The Author(s). Published by Elsevier B.V. All rights reserved.)
- Full text View on content provider's site
-
Yuan Q, Wu M, Liao Y, Liang S, Lu Y, and Lin Y
Biotechnology and bioengineering [Biotechnol Bioeng] 2023 Apr; Vol. 120 (4), pp. 1133-1146. Date of Electronic Publication: 2023 Jan 10.
- Subjects
-
Green Fluorescent Proteins chemistry, Green Fluorescent Proteins genetics, Biosynthetic Pathways, Metabolic Engineering methods, Nicotinamide Mononucleotide biosynthesis, Enzymes chemistry, and Enzymes genetics
- Abstract
-
Engineering biological systems to test new pathway variants containing different enzyme homologs is laborious and time-consuming. To tackle this challenge, a strategy was developed for rapidly prototyping enzyme homologs by combining cell-free protein synthesis (CFPS) with split green fluorescent protein (GFP). This strategy featured two main advantages: (1) dozens of enzyme homologs were parallelly produced by CFPS within hours, and (2) the expression level and activity of each homolog was determined simultaneously by using the split GFP assay. As a model, this strategy was applied to optimize a 3-step pathway for nicotinamide mononucleotide (NMN) synthesis. Ten enzyme homologs from different organisms were selected for each step. Here, the most productive homolog of each step was identified within 24 h rather than weeks or months. Finally, the titer of NMN was increased to 1213 mg/L by improving physiochemical conditions, tuning enzyme ratios and cofactor concentrations, and decreasing the feedback inhibition, which was a more than 12-fold improvement over the initial setup. This strategy would provide a promising way to accelerate design-build-test cycles for metabolic engineering to improve the production of desired products.
(© 2023 Wiley Periodicals LLC.)
- Full text View on content provider's site
-
D'Astous A, Cereza G, Papp D, Gilbert KM, Stockmann JP, Alonso-Ortiz E, and Cohen-Adad J
Magnetic resonance in medicine [Magn Reson Med] 2023 Apr; Vol. 89 (4), pp. 1401-1417. Date of Electronic Publication: 2022 Nov 28.
- Subjects
-
Brain diagnostic imaging, Algorithms, Image Processing, Computer-Assisted methods, Magnetic Resonance Imaging methods, and Software
- Abstract
-
Purpose: Introduce Shimming Toolbox ( https://shimming-toolbox.org), an open-source software package for prototyping new methods and performing static, dynamic, and real-time B0 shimming as well as B1 shimming experiments.
Methods: Shimming Toolbox features various field mapping techniques, manual and automatic masking for the brain and spinal cord, B0 and B1 shimming capabilities accessible through a user-friendly graphical user interface. Validation of Shimming Toolbox was demonstrated in three scenarios: (i) B0 dynamic shimming in the brain at 7T using custom AC/DC coils, (ii) B0 real-time shimming in the spinal cord at 3T, and (iii) B1 static shimming in the spinal cord at 7T.
Results: The B0 dynamic shimming of the brain at 7T took about 10 min to perform. It showed a 47% reduction in the standard deviation of the B0 field, associated with noticeable improvements in geometric distortions in EPI images. Real-time dynamic xyz-shimming in the spinal cord took about 5 min and showed a 30% reduction in the standard deviation of the signal distribution. B1 static shimming experiments in the spinal cord took about 10 min to perform and showed a 40% reduction in the coefficient of variation of the B1 field.
Conclusion: Shimming Toolbox provides an open-source platform where researchers can collaborate, prototype and conveniently test B0 and B1 shimming experiments. Future versions will include additional field map preprocessing techniques, optimization algorithms, and compatibility across multiple MRI manufacturers.
(© 2022 International Society for Magnetic Resonance in Medicine.)
- Full text View on content provider's site
-
Hirschhorn M, Catucci N, Day SW, Stevens RM, Tchantchaleishvili V, and Throckmorton AL
Artificial organs [Artif Organs] 2023 Apr; Vol. 47 (4), pp. 680-694. Date of Electronic Publication: 2023 Jan 10.
- Abstract
-
Background: The purpose of this research is to address ongoing device shortfalls for pediatric patients by developing a novel pediatric hybrid total artificial heart (TAH). The valveless magnetically-levitated MCS device (Dragon Heart) has only two moving parts, integrates an axial and centrifugal blood pump into a single device, and will occupy a compact footprint within the chest for the pediatric patient population.
Methods: Prior work on the Dragon Heart focused on the development of pump designs to achieve hemodynamic requirements. The impeller of these pumps was shaft-driven and thus could not be integrated for testing. The presented research leverages an existing magnetically levitated axial flow pump and focuses on centrifugal pump development. Using the axial pump diameter as a geometric constraint, a shaftless, magnetically supported centrifugal pump was designed for placement circumferentially around the axial pump domain. The new design process included the computational analysis of more than 50 potential centrifugal impeller geometries. The resulting centrifugal pump designs were prototyped and tested for levitation and no-load rotation, followed by in vitro testing using a blood analog. To meet physiologic demands, target performance goals were pressure rises exceeding 90 mm Hg for flow rates of 1-5 L/min with operating speeds of less than 5000 RPM.
Results: Three puck-shaped, channel impellers for the centrifugal blood pump were selected based on achieving performance and space requirements for magnetic integration. A quasi-steady flow analysis revealed that the impeller rotational position led to a pulsatile component in the pressure generation. After prototyping, the centrifugal prototypes (3, 4, and 5 channeled designs) demonstrated levitation and no-load rotation. Hydraulic experiments established pressure generation capabilities beyond target requirements. The pressure-flow performance of the prototypes followed expected trends with a dependence on rotational speed. Pulsatile blood flow was observed without pump-speed modulation due to rotating channel passage frequency.
Conclusion: The results are promising in the advancement of this pediatric TAH. The channeled impeller design creates pressure-flow curves that are decoupled from the flow rate, a benefit that could reduce the required controller inputs and improve treatment of hypertensive patients.
(© 2022 International Center for Artificial Organs and Transplantation and Wiley Periodicals LLC.)
- Full text View on content provider's site
-
Alizadeh N and Salimi A
Analytical methods : advancing methods and applications [Anal Methods] 2023 Mar 29. Date of Electronic Publication: 2023 Mar 29.
- Abstract
-
We present a novel electrochemical microfluidic device for the sensitive and selective detection of hydrogen peroxide (H 2 O 2 ) through a VO 2 nanostructure enzyme mimic. The low-cost ($0.50) microfluidic chip was fabricated using a simple and rapid prototyping technique via three syringe needles. Each needle played the role of an electrode (working, reference, and counter), and was connected by micro-hoses to a construction of the electrochemical microfluidic chip. The colloidal VO 2 nanoflakes with peroxidase-like activity could be easily transferred on to the electrodes by a syringe, for development of a novel electrochemical platform to enable the detection of H 2 O 2 . The unique microfluidic electrochemical sensor delivered a wide linear dynamic range from 0.5 to 300 μM, with a limit of detection of 0.14 μM. The facile, rapid, sensitive, and selective as-fabricated H 2 O 2 sensors were proven to be appropriate for the real-time monitoring of H 2 O 2 released from PC12 cells. The integration of a microfluidic sensor with an enzyme mimic nanostructure is essentially a promising strategy for the low-cost and accurate monitoring of physiological processes.
- Full text View on content provider's site
-
Ouyang W, Xu X, Lu W, Zhao N, Han F, and Chen SC
Nature communications [Nat Commun] 2023 Mar 27; Vol. 14 (1), pp. 1716. Date of Electronic Publication: 2023 Mar 27.
- Abstract
-
There has been a compelling demand of fabricating high-resolution complex three-dimensional (3D) structures in nanotechnology. While two-photon lithography (TPL) largely satisfies the need since its introduction, its low writing speed and high cost make it impractical for many large-scale applications. We report a digital holography-based TPL platform that realizes parallel printing with up to 2000 individually programmable laser foci to fabricate complex 3D structures with 90 nm resolution. This effectively improves the fabrication rate to 2,000,000 voxels/sec. The promising result is enabled by the polymerization kinetics under a low-repetition-rate regenerative laser amplifier, where the smallest features are defined via a single laser pulse at 1 kHz. We have fabricated large-scale metastructures and optical devices of up to centimeter-scale to validate the predicted writing speed, resolution, and cost. The results confirm our method provides an effective solution for scaling up TPL for applications beyond laboratory prototyping.
(© 2023. The Author(s).)
- Full text View on content provider's site
-
Nkhwa S, Montshiwa T, de Beer D, Booysen G, van den Heever C, Els J, Heydenrych A, and Kebaetse M
3D printing in medicine [3D Print Med] 2023 Mar 23; Vol. 9 (1), pp. 7. Date of Electronic Publication: 2023 Mar 23.
- Abstract
-
Background: Botswana, like most sub-Sahara African nations, uses conventional orthopaedic implants that are sourced from major manufactures in the West. The implants are mass-produced and designed with universal configurations to fit an average patient. During surgery, surgeons thus sometimes bend the implants to match the individual bone anatomy, especially for paediatric patients and those with unique deformities, thus risking implant failure. The purpose of this project was to show the feasibility of developing safe and effective patient-specific orthopaedic implants in a low-resourced market.
Methods: CT Scan slice files of a paediatric patient with Ollier's disease were used to reconstruct the lower limb anatomy. The resultant files were 3D printed into prototypes that showed severe right knee valgus deformity. The surgeon used the prototype to plan for corrective femoral osteotomy and the required implant. The implant design and planned surgery were subsequently simulated on the Medical Design Studio software for proper fitting before final implant printing. Surgery was then performed, followed by 12 weeks of physiotherapy.
Results: Post-surgical x-rays demonstrated good implant positioning and knee joint alignment. At 18 months of post-surgical follow-up, the child was pain-free, could perform full squats, and ambulation was near-normal, without the use of an assistive device.
Conclusions: It is feasible to develop effective, patient-specific implants for selected orthopaedic cases in a low-resourced country. This work could improve surgical and rehabilitation outcomes for selected paediatric patients and those with severe bone deformities.
(© 2023. The Author(s).)
- Full text View on content provider's site
11. Rapid prototyping for quantifying belief weights of competing hypotheses about emergent diseases. [2023]
-
Robertson EP, Walsh DP, Martin J, Work TM, Kellogg CA, Evans JS, Barker V, Hawthorn A, Aeby G, Paul VJ, Walker BK, Kiryu Y, Woodley CM, Meyer JL, Rosales SM, Studivan M, Moore JF, Brandt ME, and Bruckner A
Journal of environmental management [J Environ Manage] 2023 Mar 21; Vol. 337, pp. 117668. Date of Electronic Publication: 2023 Mar 21.
- Abstract
-
Emerging diseases can have devastating consequences for wildlife and require a rapid response. A critical first step towards developing appropriate management is identifying the etiology of the disease, which can be difficult to determine, particularly early in emergence. Gathering and synthesizing existing information about potential disease causes, by leveraging expert knowledge or relevant existing studies, provides a principled approach to quickly inform decision-making and management efforts. Additionally, updating the current state of knowledge as more information becomes available over time can reduce scientific uncertainty and lead to substantial improvement in the decision-making process and the application of management actions that incorporate and adapt to newly acquired scientific understanding. Here we present a rapid prototyping method for quantifying belief weights for competing hypotheses about the etiology of disease using a combination of formal expert elicitation and Bayesian hierarchical modeling. We illustrate the application of this approach for investigating the etiology of stony coral tissue loss disease (SCTLD) and discuss the opportunities and challenges of this approach for addressing emergent diseases. Lastly, we detail how our work may apply to other pressing management or conservation problems that require quick responses. We found the rapid prototyping methods to be an efficient and rapid means to narrow down the number of potential hypotheses, synthesize current understanding, and help prioritize future studies and experiments. This approach is rapid by providing a snapshot assessment of the current state of knowledge. It can also be updated periodically (e.g., annually) to assess changes in belief weights over time as scientific understanding increases. Synthesis and applications: The rapid prototyping approaches demonstrated here can be used to combine knowledge from multiple experts and/or studies to help with fast decision-making needed for urgent conservation issues including emerging diseases and other management problems that require rapid responses. These approaches can also be used to adjust belief weights over time as studies and expert knowledge accumulate and can be a helpful tool for adapting management decisions.
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2023 Elsevier Ltd. All rights reserved.)
- Full text View on content provider's site
-
Bulanda K, Oleksy M, and Oliwa R
Polymers [Polymers (Basel)] 2023 Mar 21; Vol. 15 (6). Date of Electronic Publication: 2023 Mar 21.
- Abstract
-
As part of this work, polymer composites based on polycarbonate/acrylonitrile-butadiene-styrene (PC/ABS) were obtained and used in 3D printing technology, particularly Melted Extrusion Modeling (MEM) technology. The influence of selected fillers on the properties of the obtained composites was investigated. For this purpose, modified fillers such as silica modified with alumina, bentonite modified with a quaternary ammonium salt, and hybrid lignin/silicon dioxide filler were introduced into the PC/ABS matrix. In the first part of this work, polymer blends and their composites containing 1.5-3 wt. of the filler were used to obtain the filament using the proprietary technological line. Moldings for testing the performance properties were obtained using additive manufacturing techniques and injection molding. In the subsequent part of this work, rheological properties (mass flow rate (MFR) and viscosity curves) and mechanical properties (Rockwell hardness and static tensile strength with Young's modulus) were examined. The structures of the obtained composites were also determined by scanning electron microscopy (SEM/EDS). The obtained results confirmed the results obtained from a wide-angle X-ray scattering analysis (WAXS). In turn, the physicochemical properties were characterized on the basis of the results of tests using thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). Based on the obtained results, it was found that the introduced modified additives had a significant impact on the processing and functional properties of the tested composites.
- Full text View on content provider's site
-
Marshall ADA, Hasdianda MA, Miyawaki S, Jambaulikar GD, Cao C, Chen P, Baugh CW, Zhang H, McCabe J, Steinbach L, King S, Friedman J, Su J, Landman AB, and Chai PR
JMIR formative research [JMIR Form Res] 2023 Mar 21; Vol. 7, pp. e44725. Date of Electronic Publication: 2023 Mar 21.
- Abstract
-
Background: Electronic paper (E-paper) screens use electrophoretic ink to provide paper-like low-power displays with advanced networking capabilities that may potentially serve as an alternative to traditional whiteboards and television display screens in hospital settings. E-paper may be leveraged in the emergency department (ED) to facilitate communication. Providing ED patient status updates on E-paper screens could improve patient satisfaction and overall experience and provide more equitable access to their health information.
Objective: We aimed to pilot a patient-facing digital whiteboard using E-paper to display relevant orienting and clinical information in real time to ED patients. We also sought to assess patients' satisfaction after our intervention and understand our patients' overall perception of the impact of the digital whiteboards on their stay.
Methods: We deployed a 41-inch E-paper digital whiteboard in 4 rooms in an urban, tertiary care, and academic ED and enrolled 110 patients to understand and evaluate their experience. Participants completed a modified Hospital Consumer Assessment of Health Care Provider and Systems satisfaction questionnaire about their ED stay. We compared responses to a matched control group of patients triaged to ED rooms without digital whiteboards. We designed the digital whiteboard based on iterative feedback from various departmental stakeholders. After establishing IT infrastructure to support the project, we enrolled patients on a convenience basis into a control and an intervention (digital whiteboard) group. Enrollees were given a baseline survey to evaluate their comfort with technology and an exit survey to evaluate their opinions of the digital whiteboard and overall ED satisfaction. Statistical analysis was performed to compare baseline characteristics as well as satisfaction.
Results: After the successful prototyping and implementation of 4 digital whiteboards, we screened 471 patients for inclusion. We enrolled 110 patients, and 50 patients in each group (control and intervention) completed the study protocol. Age, gender, and racial and ethnic composition were similar between groups. We saw significant increases in satisfaction on postvisit surveys when patients were asked about communication regarding delays (P=.03) and what to do after discharge (P=.02). We found that patients in the intervention group were more likely to recommend the facility to family and friends (P=.04). Additionally, 96% (48/50) stated that they preferred a room with a digital whiteboard, and 70% (35/50) found the intervention "quite a bit" or "extremely" helpful in understanding their ED stay.
Conclusions: Digital whiteboards are a feasible and acceptable method of displaying patient-facing data in the ED. Our pilot suggested that E-paper screens coupled with relevant, real-time clinical data and packaged together as a digital whiteboard may positively impact patient satisfaction and the perception of the facility during ED visits. Further study is needed to fully understand the impact on patient satisfaction and experience.
Trial Registration: ClinicalTrials.gov NCT04497922; https://clinicaltrials.gov/ct2/show/NCT04497922.
(©Andrew D A Marshall, Mohammad Adrian Hasdianda, Steven Miyawaki, Guruprasad D Jambaulikar, Chenze Cao, Paul Chen, Christopher W Baugh, Haipeng Zhang, Jonathan McCabe, Lee Steinbach, Scott King, Jason Friedman, Jennifer Su, Adam B Landman, Peter Ray Chai. Originally published in JMIR Formative Research (https://formative.jmir.org), 21.03.2023.)
- Full text View on content provider's site
-
Rasor BJ, Karim AS, Alper HS, and Jewett MC
ACS synthetic biology [ACS Synth Biol] 2023 Mar 17; Vol. 12 (3), pp. 904-908. Date of Electronic Publication: 2023 Feb 27.
- Subjects
-
Cell Extracts, Freezing, Saccharomyces cerevisiae metabolism, and Bacteria
- Abstract
-
Cell-free synthetic biology enables rapid prototyping of biological parts and synthesis of proteins or metabolites in the absence of cell growth constraints. Cell-free systems are frequently made from crude cell extracts, where composition and activity can vary significantly based on source strain, preparation and processing, reagents, and other considerations. This variability can cause extracts to be treated as black boxes for which empirical observations guide practical laboratory practices, including a hesitance to use dated or previously thawed extracts. To better understand the robustness of cell extracts over time, we assessed the activity of cell-free metabolism during storage. As a model, we studied conversion of glucose to 2,3-butanediol. We found that cell extracts from Escherichia coli and Saccharomyces cerevisiae subjected to an 18-month storage period and repeated freeze-thaw cycles retain consistent metabolic activity. This work gives users of cell-free systems a better understanding of the impacts of storage on extract behavior.
- Full text View on content provider's site
-
Saiger MJ, Deterding S, and Gega L
JMIR serious games [JMIR Serious Games] 2023 Mar 16; Vol. 11, pp. e42680. Date of Electronic Publication: 2023 Mar 16.
- Abstract
-
Background: User involvement is widely accepted as key for designing effective applied games for health. This especially holds true for children and young people as target audiences, whose abilities, needs, and preferences can diverge substantially from those of adult designers and players. Nevertheless, there is little shared knowledge about how concretely children and young people have been involved in the design of applied games, let alone consensus guidance on how to do so effectively.
Objective: The aim of this scoping review was to describe which user involvement methods have been used in the design of applied games with children and young people, how these methods were implemented, and in what roles children and young people were involved as well as what factors affected their involvement.
Methods: We conducted a systematic literature search and selection across the ACM Digital Library, IEEE Xplore, Scopus, and Web of Science databases using State of the Art through Systematic Review software for screening, selection, and data extraction. We then conducted a qualitative content analysis on the extracted data using NVivo.
Results: We retrieved 1085 records, of which 47 (4.33%) met the eligibility criteria. The chief involvement methods were participatory design (20/47, 43%) and co-design (16/47, 37%), spanning a wide range of 45 concrete activities with paper prototyping, group discussions, and playtesting being the most frequent. In only half of the studies (24/47, 51%), children and young people participated as true design partners. Our qualitative content analysis suggested 5 factors that affect their successful involvement: comprehension, cohesion, confidence, accessibility, and time constraints.
Conclusions: Co-design, participatory design, and similar high-level labels that are currently used in the field gloss over very uneven degrees of participation in design and a wide variety of implementations that greatly affect actual user involvement. This field would benefit from more careful consideration and documentation of the reason of user involvement. Future research should explore concrete activities and configurations that can address the common challenges of involving children and young people, such as comprehension, cohesion, confidence, and accessibility.
(©Michael John Saiger, Sebastian Deterding, Lina Gega. Originally published in JMIR Serious Games (https://games.jmir.org), 16.03.2023.)
- Full text View on content provider's site
-
Graham AK, Kosmas JA, and Massion TA
Current psychiatry reports [Curr Psychiatry Rep] 2023 Mar 16. Date of Electronic Publication: 2023 Mar 16.
- Abstract
-
Purpose of Review: Digital (i.e., online, mobile) interventions have potential to increase access to care for people with eating disorders, but engagement with digital interventions has been challenging. Human-centered design is a methodology that centralizes the design of technologies on the people who will be using them and the settings in which they will be implemented, to yield solutions with high engagement and clinical impact. The paper presents an overview of the human-centered design process, followed by a review of publications that have applied design methods to digital interventions for eating disorders.
Recent Findings: Design research has been conducted via needs assessments, prototyping and usability studies, and during ongoing delivery of digital eating disorder interventions. There has been growing research applying design methods to digital interventions for eating disorders. Additional opportunities include designing for implementation, designing for equity, and designing for the optimization of digital interventions over time.
(© 2023. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)
- Full text View on content provider's site
-
Zhang W, Wu X, Li L, Zou C, and Chen Y
ACS applied materials & interfaces [ACS Appl Mater Interfaces] 2023 Mar 15; Vol. 15 (10), pp. 13517-13525. Date of Electronic Publication: 2023 Mar 01.
- Abstract
-
Vanadium dioxide (VO 2 ) is widely employed in developing tunable optoelectronic devices due to its significant changes in optical and electric properties upon phase transition. To fabricate the VO 2 -based functional devices down to the micro/nanoscale, a high-resolution processing technique is in demand. Scanning probe lithography (SPL) on the basis of a tip-induced electric field provides a promising approach for prototyping. Here, we demonstrated a precise VO 2 etching strategy by direct writing on a VO 2 film with a negative tip bias and subsequent sonication removal of the written area. The effects of bias voltage, sonication, and thermal treatment as well as the mechanical difference between the tip-modulated area and the pristine VO 2 film were investigated systematically. The results show that VO 2 can be etched layer by layer via alternately repeating tip modulation and sonication, and arbitrary patterns can be written. Based on this route, we designed a kind of metasurface by arranging VO 2 -gold nanoblocks with different sizes and heights for spectrally selective tunable reflectivity in near- and mid-infrared. This electric-field SPL method demonstrates the prominent advantages of high resolution down to several tens of nanometers, quasi-3D patterning, and resist-free maskless direct writing, which should be applicable for prototyping other micro/nanodevices.
- Full text View on content provider's site
-
Schulze-Meeßen L and Hamborg KC
Applied ergonomics [Appl Ergon] 2023 Mar 14; Vol. 110, pp. 104012. Date of Electronic Publication: 2023 Mar 14.
- Abstract
-
In an experiment so-termed sociotechnical prototypes based on either a graphical or a textual representation of an envisioned work system were evaluated with regard to their ability to communicate a design vision to people involved in a participatory design process. Results of the study reveal, in line with hypotheses, that the graphical prototype, in contrast to the textual one, was significantly better accepted as well as faster explored and evaluated. Moreover, results support the hypothesis that the graphical sociotechnical prototype helps to build up a more accurate mental representation of the system with regard to its elements (e.g. job roles, tasks). However, no positive effect on the mental representation of the system in terms of the relations between its elements (e.g. which role performs which task?) was found. Finally, practical implications and perspectives for further development of the sociotechnical prototyping approach to envision future work systems are discussed.
Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
(Copyright © 2023 Elsevier Ltd. All rights reserved.)
- Full text View on content provider's site
-
Wei Y, Wang T, Wang Y, Zeng S, Ho YP, and Ho HP
Micromachines [Micromachines (Basel)] 2023 Mar 14; Vol. 14 (3). Date of Electronic Publication: 2023 Mar 14.
- Abstract
-
In this paper, we report a simple, rapid, low-cost, biocompatible, and detachable microfluidic chip fabrication method for customized designs based on Parafilm ® . Here, Parafilm ® works as both a bonding agent and a functional membrane. Its high ultimate tensile stress (3.94 MPa) allows the demonstration of high-performance actuators such as microvalves and micropumps. By laser ablation and the one-step bonding of multiple layers, 3D structured microfluidic chips were successfully fabricated within 2 h. The consumption time of this method (~2 h) was 12 times less than conventional photolithography (~24 h). Moreover, the shear stress of the PMMA-Parafilm ® -PMMA specimens (0.24 MPa) was 2.13 times higher than that of the PDMS-PDMS specimens (0.08 MPa), and 0.56 times higher than that of the PDMS-Glass specimens (0.16 MPa), showing better stability and reliability. In this method, multiple easily accessible materials such as polymethylmethacrylate (PMMA), PVC, and glass slides were demonstrated and well-incorporated as our substrates. Practical actuation devices that required high bonding strength including microvalves and micropumps were fabricated by this method with high performance. Moreover, the biocompatibility of the Parafilm ® -based microfluidic devices was validated through a seven-day E. coli cultivation. This reported fabrication scheme will provide a versatile platform for biochemical applications and point-of-care diagnostics.
- Full text View on content provider's site
-
Taneja S, Tenpas W, Jain M, Alfonsi P, Ratagiri A, Saterbak A, and Theiling J
Advances in simulation (London, England) [Adv Simul (Lond)] 2023 Mar 09; Vol. 8 (1), pp. 8. Date of Electronic Publication: 2023 Mar 09.
- Abstract
-
Background: Shoulder dislocations are common occurrences, yet there are few simulation devices to train medical personnel on how to reduce these dislocations. Reductions require a familiarity with the shoulder and a nuanced motion against strong muscle tension. The goal of this work is to describe the design of an easily replicated, low-cost simulator for training shoulder reductions.
Materials and Methods: An iterative, stepwise engineering design process was used to design and implement ReducTrain. A needs analysis with clinical experts led to the selection of the traction-countertraction and external rotation methods as educationally relevant techniques to include. A set of design requirements and acceptance criteria was established that considered durability, assembly time, and cost. An iterative prototyping development process was used to meet the acceptance criteria. Testing protocols for each design requirement are also presented. Step-by-step instructions are provided to allow the replication of ReducTrain from easily sourced materials, including plywood, resistance bands, dowels, and various fasteners, as well as a 3D-printed shoulder model, whose printable file is included at a link in the Additional file 1: Appendix.
Results: A description of the final model is given. The total cost for all materials for one ReducTrain model is under US $200, and it takes about 3 h and 20 min to assemble. Based on repetitive testing, the device should not see any noticeable changes in durability after 1000 uses but may exhibit some changes in resistance band strength after 2000 uses.
Discussion: The ReducTrain device fills a gap in emergency medicine and orthopedic simulation. Its wide variety of uses points to its utility in several instructional formats. With the rise of makerspaces and public workshops, the construction of the device can be easily completed. While the device has some limitations, its robust design allows for simple upkeep and a customizable training experience.
Conclusion: A simplified anatomical design allows for the ReducTrain model to serve as a viable training device for shoulder reductions.
(© 2023. The Author(s).)